Desiccant dehumidifiers are more economical than refrigeration based dehumidifiers at lower temperatures and lower moisture levels. Typically, a desiccantsystem is utilized for applications below 45%RH down to 1%RH. In many applications, a DX or chilled water pre cool coil is mounted directly at the dehumidifier inlet. This allows for removal much of the initial heat and moisture prior to entering the dehumidifier where the moisture is reduced even further.

  • DryMax CDM-115

    Height (inch) 13.3
    Width (inch) 13.0
    Depth (inch) 15.0
    Weight(lbs) 37.5
    Voltage 110
    Phase 1
    Frequency(Hz) 60
    Power(kW) 0.8
    Current(A) 7.5
    Process Airflow(cfm) 115
    Regen Airflow(cfm) 38
    Process Duct Size (inch) 5.0
    Regen Duct Size (inch) 2.75
    Noise Level(dba) 67
    Typical Extraction(ppd) 36
    Min Operating Temp (?F) -4
    Max OperatingTemp (?F) 104
    DETAILS
  • DryMax CDM-197

    Height (inch) 16.5
    Width (inch) 15.75
    Depth (inch) 21.25
    Weight(lbs) 59.5
    Voltage 220
    Phase 1
    Frequency(Hz) 60
    Power(kW) 1.8
    Current(A) 8.0
    Process Airflow(cfm) 197
    Regen Airflow(cfm) 119
    Process Duct Size (inch) 5.0
    Regen Duct Size (inch) 4.0
    Noise Level(dba) 67
    Typical Extraction(ppd) 71.5
    Min Operating Temp (?F) -4
    Max OperatingTemp (?F) 104
    DETAILS
  • DryMax CDM-1765

    Height (inch) 55
    Width (inch) 85
    Depth (inch) 39
    Weight(lbs) 1,114
    Voltage options 220 or 460
    Phase 3
    Frequency(Hz) 60
    Total Power(kW) 25
    Regeneration Heater Power Requirements (kW) 22
    Process Airflow Maximum ? Dry Air (cfm) 1,765
    Process Airflow Static Pressure (WG) 5
    Regen Airflow Nominal ? Wet Air (cfm) 423
    Regen Airflow Static Pressure (WG) 3.2
    Process Air Outlet Dia (inch) 16
    Process Air Inlet (L X W) 29 X 21
    Regen Air Outlet Dia (inch) 10
    Regen Air Inlet (L X W) 19 X 19
    Rotor Wheel Speed (rph) 10.2
    Rotor Size dia X depth (inch) 25.5 X 7.9
    Typical Extraction @ 60?F 60%RH (ppd) 840
    Min Operating Temperature (?F) -4
    DETAILS
  • DryMax CDM-3531

    Height (inch) 55
    Width (inch) 85
    Depth (inch) 39
    Weight(lbs) 1,234
    Voltage options 220 or 460
    Phase 3
    Frequency(Hz) 60
    Total Power(kW) 50
    Regeneration Heater Power Requirements (kW) 45
    Process Airflow Maximum ? Dry Air (cfm) 3,531
    Process Airflow Static Pressure (WG) 4.4
    Regen Airflow Nominal ? Wet Air (cfm) 835
    Regen Airflow Static Pressure (WG) 5.4
    Process Air Outlet Dia (inch) 16
    Process Air Inlet (L X W) 29 X 21
    Regen Air Outlet Dia (inch) 10
    Regen Air Inlet (L X W) 19 X 19
    Rotor Wheel Speed (rph) 10.2
    Rotor Size dia X depth (inch) 33.5 X 7.9
    Typical Extraction @ 60?F 60%RH (ppd) 1,641
    Min Operating Temperature (?F) -4
    DETAILS
  • DryMax CDMTH

    Depending on particular configuration, following components can be used to achieve design conditions:

    • Bypass
    • Chilled water cooling
    • DX or chilled water
    • Food grade construction
    • Humidification
    • Humidity control system

    Please contact your nearest Drymax representative to discuss your project to get expert advise.

    DETAILS
  • DryMax CDM-7000

    Height (inch) 70
    Width (inch) 95
    Depth (inch) 55
    Weight(lbs) 2,998
    Voltage options 220 or 460
    Phase 3
    Frequency(Hz) 60
    Total Power(kW) 50
    Regeneration Heater Power Requirements (kW) 84
    Process Airflow Maximum ? Dry Air (cfm) 7,062
    Process Airflow Static Pressure (WG) 3.6
    Regen Airflow Nominal ? Wet Air (cfm) 1,530
    Regen Airflow Static Pressure (WG) 4.4
    Process Air Outlet Dia (inch) 18
    Process Air Inlet (L X W) 39 X 29
    Regen Air Outlet Dia (inch) 14
    Regen Air Inlet (L X W) 23 X 23
    Rotor Wheel Speed (rph) 10.2
    Rotor Size dia X depth (inch) 49.2 X 7.9
    Typical Extraction @ 60?F 60%RH (ppd) 3,173
    Min Operating Temperature (?F) -4
    DETAILS